C00636, C00637, C00691 – Lenze E94AxHE Servo Drives 9400 HighLine (Firmware 01-37) User Manual

Page 597: C00692, C00693, C00694, 9400 highline | parameter setting & configuration

Advertising
background image

L

Firmware 1.37 - 09/2006

597

9400 HighLine | Parameter setting & configuration

Parameter reference

Parameter list | C00636

C00636

C00637

C00691

C00692

C00693

C00694

Parameter | Name:

C00636 | Resp. to new module in MXI1

Data type: UNSIGNED_32

Index: 23939

d

= 5D83

h

Selection list

(Lenze setting printed in bold)

0 No response
1 Error
3 Quick stop by trouble
4 Warning locked
5 Warning
6 Information

;

Read access ; Write access … CINH … PLC STOP … No transfer … COM … MOT

Parameter | Name:

C00637 | Resp. to new module in MXI2

Data type: UNSIGNED_32

Index: 23938

d

= 5D82

h

Selection list

(Lenze setting printed in bold)

0 No response
1 Error
3 Quick stop by trouble
4 Warning locked
5 Warning
6 Information

;

Read access ; Write access … CINH … PLC STOP … No transfer … COM … MOT

Parameter | Name:

C00691 | Total speed setpoint

Data type: INTEGER_32

Index: 23884

d

= 5D4C

h

Display range

(min. value | unit | max. value)

-200.00

%

200.00

;

Read access … Write access … CINH … PLC STOP … No transfer … COM … MOT Scaling factor: 100

Parameter | Name:

C00692 | Speed setpoint

Data type: INTEGER_32

Index: 23883

d

= 5D4B

h

Display range

(min. value | unit | max. value)

-200.00

%

200.00

;

Read access … Write access … CINH … PLC STOP … No transfer … COM … MOT Scaling factor: 100

Parameter | Name:

C00693 | Actual speed

Data type: INTEGER_32

Index: 23882

d

= 5D4A

h

Display range

(min. value | unit | max. value)

-200.00

%

200.00

;

Read access … Write access … CINH … PLC STOP … No transfer … COM … MOT Scaling factor: 100

Parameter | Name:

C00694 | Speed controller output

Data type: INTEGER_32

Index: 23881

d

= 5D49

h

Display range

(min. value | unit | max. value)

-200.00

%

200.00

;

Read access … Write access … CINH … PLC STOP … No transfer … COM … MOT Scaling factor: 100