2 dead time compensation, 9400 highline | parameter setting & configuration – Lenze E94AxHE Servo Drives 9400 HighLine (Firmware 01-37) User Manual

Page 131

Advertising
background image

L

Firmware 1.37 - 09/2006

131

9400 HighLine | Parameter setting & configuration

I/O terminals

Touch probe detection

7.7.2

Dead time compensation

For dead time compensation during the detection of the touch probe event, it is possible to

select a delay time (touch probe delay) in

C02810

for each touch probe channel, which will

be considered in the touch probe calculation.

[7-4]

Dead time compensation (principle)

r

Filtering of the digital inputs influences the electrical detection of the touch probe, i.e.

the DIx delay time set in

C02830

for the digital inputs must be considered in the delay

time

C02810

.

r

For the optional digital frequency input/output the delay times must be set via special

parameters:
– C13021 or C14021: TP delay time - digital frequency input.
– C13061 or C14061: TP delay time - digital frequency output.



Mechanical event: Switch is closed



Electrical event: Closed switch contact is registered

• Can, e.g. be delayed by flying times of the mechanical contact or filter.



Value and position determination for the real (mechanical) event, the determined values are transferred to

the application

n

Delay time (dead time) between mechanical and electrical event

• This dead time can be compensated by a corresponding setting in

C02810

.

o

Time considered by touch probe calculation

• If more than one task cycle has passed, the history buffer finds the two actual position values between

which the physical event has occurred.

Data

processing

Application

Data

processing

Application

Data

processing

Application

Task cycle

Task cycle

Task cycle

t

Position

t

0

1

2

Œ

Delay time



Touch probe received

Advertising