9400 HighLine | Parameter setting & configuration

TAs for positioning tasks

TA "Multi-purpose positioning" | Assignment of the I/O terminals

13.2.2

Assignment of the I/O terminals

13.2.2.1

Setpoint and control signals
The following tables contain the Lenze assignment of the analog and digital inputs for the

technology application "Multi-purpose positioning".

Analog inputs

Digital inputs

Terminal X3

Signal (Lenze setting)

AI1-

AI1+

Selection for speed override

Speed/acceleration override (C 399)

AI2-

AI2+

Selection for acceleration override

Speed/acceleration override (C 399)

I/O terminals Analog inputs (C 117)

Terminal X5

Signal (Lenze setting)

DI1

Quick stop

• If DI1 is set to LOW level, the positioning program is interrupted and drive is decelerated

to standstill within the deceleration time set for the quick stop function independent of

the setpoint selection.

• After the quick stop function is deactivated, a new LOW/HIGH edge is required at DI6 in

order that the positioning program is continued with the next step.

Quick stop (C 402)

DI2

Connection of reference switch/touch probe sensor

Action type "Homing" (C 382)

DI3

DI4

Connection of travel range limit switch for basic function "

Limiter

".

(C 403)

• DI3 = positive travel range limit switch, DI4 = negative travel range limit switch.

• The inputs respond to the FALSE state (fail-safe).

DI5

Reset error and positioning program

• By means of a LOW-HIGH edge an existing error status can be reset if the cause of the

fault is removed. At the same time the positioning program is reset.

DI6

Start positioning program

Control of the sequence table (C 389)

DI7

Stop positioning program (break)

Control of the sequence table (C 389)

DI8

Sequencer input 8 for positioning program

• The action types "Positioning", Branching", "Waiting" and "Stand-by" have the parameter

"Input for...". If this is non-zero, it describes the number of the sequencer input where the

positioning program awaits the level defined before it executes the action. In the Lenze

assignment the terminal DI8 is available as sequencer input 8.

Program flow (C 378)

I/O terminals Digital inputs (C 123)

A1+

A1-

A1-

A1R

A2+

A2-

GI

RFR

DI1

DI2

DI3

DI4

DI5

DI6

DI7

DI8