6 trigger/cursor settings, 7 horizontal settings, 8 recording settings – Lenze E94AxHE Servo Drives 9400 HighLine (Firmware 01-37) User Manual

Page 420: Trigger/cursor settings, Horizontal settings, Recording settings, 9400 highline | parameter setting & configuration

Advertising
background image

9400 HighLine | Parameter setting & configuration

Oscilloscope

User interface

420

Firmware 1.37 - 09/2006

L

14.3.6

Trigger/cursor settings

Trigger

Use the Trigger tab to configure the trigger condition.

Selecting the trigger condition

(C 422)

Cursor

If the Cursor tab is on top, you can use a vertical measuring line to read individual

measured values of a selectable channel in the oscilloscope. Using a second vertical

measuring line, it is possible to indicate the difference between two measured values.

Reading individual measured values

(C 426)

14.3.7

Horizontal settings

Use the Horizontal group box to select the time base and the horizontal position.

Selecting the recording time/sample rate

(C 422)

14.3.8

Recording settings

Use the Recording group box to select the sample rate and start recording.

r

Since the measured data memory has a limited capacity, a compromise must be found

between the sample rate and the recording time that results from the time base

setting.

Selecting the recording time/sample rate

(C 422)

Group box

Meaning

Channel

Channel selection

Value

Display of the value measured at the position of the active measuring line

Difference

Display of the difference between the values measured at the two measuring lines

Input field

Meaning

Time base [1/Div]

Selection of time base

• The current time base setting multiplied by ten results in the recording time.

• Change the time base to stretch or compress measurements that have already been

completed.

Position

Selection of the horizontal display position

• The position value can be directly entered into the input field or selected by using the

arrow buttons.

• When the arrow buttons are used and the <Ctrl> key is pressed, you can increase the step

width to accelerate the shift.

Advertising