L

Firmware 1.37 - 09/2006

133

9400 HighLine | Parameter setting & configuration

I/O terminals

Touch probe detection

7.7.4

System block "LS_TouchProbeMotor"

The system block LS_TouchProbeMotor displays the touch probe channel, which is

assigned to the motor encoder zero pulse, in the function block editor.

7.7.5

System block "LS_TouchProbeLoad"

The system block LS_TouchProbeLoad displays the touch probe channel, which is assigned

to the load encoder zero pulse, in the function block editor.

Output

Data type

Value/meaning

TPM_dnTouchProbeTimeLag

DINT

Scaled time stamp for processing the touch probe event with the

FB L_SdTouchProbe.

TPM_bTouchProbeReceived

BOOL

Status signal "Touch probe detected"

• Status is only set for one task cycle.

TRUE Touch probe event has been activated.

TPM_bTouchProbeLost

BOOL

Status signal "Touch probe(s) lost"

• Status is only set for one task cycle.

TRUE More than one touch probe event has been activated in the task run

time and could therefore not be detected.

TPM_dnTouchProbeTimeLag

TPM_bTouchProbeReceived

TPM_bTouchProbeLost

LS_TouchProbeMotor

TP

Output

Data type

Value/meaning

TPL_dnTouchProbeTimeLag

DINT

Scaled time stamp for processing the touch probe event with the

FB L_SdTouchProbe.

TPL_bTouchProbeReceived

BOOL

Status signal "Touch probe detected"

• Status is only set for one task cycle.

TRUE Touch probe event has been activated.

TPL_bTouchProbeLost

BOOL

Status signal "Touch probe(s) lost"

• Status is only set for one task cycle.

TRUE More than one touch probe event has been activated in the task run

time and could therefore not be detected.

TPL_dnTouchProbeTimeLag

TPL_bTouchProbeReceived

TPL_bTouchProbeLost

LS_TouchProbeLoad

TP

Advertising