Standard TAs

TA "Actuator – speed" | Speed setpoint conditioning

250

Firmware 1.37 - 09/2006

L

11.2.4

Speed setpoint conditioning

[11-4] Speed setpoint conditioning (schematic diagram)

The speed setpoint is defined in the Lenze setting via the analog input 1 and take place in

both directions (bipolar) and accordingly the driven machine part moves forward or

backward.

r

Parameter setting: Tab Application parameter  Dialog level Overview

Gain

Invert setpoint

Selection

LS_Speed...

M

Speed
setpoint

DI2

DI3

DI4

OUT

IN

Ramp generator

%

1

%

2

%

15

Fixed setpoints

Status

machine

(basic drive

functions)

Speed setpoint

AIN1

M

v

Parameters

Lenze setting

Value Unit

C03002

Setpoint gain

100.00 %

Setpoint inputs of the function

Signal configuration

Lenze setting

Setpoint input

(Multiplexer parameters)

AIn 1  Speed setpoint

C03000