10 limiter, Limiter, Range limit switches/software limit positions) – Lenze E94AxHE Servo Drives 9400 HighLine (Firmware 01-37) User Manual

Page 200: C 200), Ication, e.g. via the basic function, The basic function, Und in the description of the basic function, Nction

Advertising
background image

9400 HighLine | Parameter setting & configuration

Basic drive functions

Limiter

200

Firmware 1.37 - 09/2006

L

9.10

Limiter

The basic function "Limiter" monitors the travel range limits via limit switches and

parameterised software limit positions and can lead the drive to defined limit ranges when

being asked accordingly by the safety module.

See also:

Safety engineering

(C 135)

Note!

In order that the basic function "Limiter", after being asked accordingly by the

safety module, can lead the drive to the defined limit ranges before the limits set

for the safety module are reached which stops the drive, the limit values for the

basic function "Limiter" must be set lower than the limit values for the safety

module!



Danger!

The safety is exclusively ensured by the safety module!
When the request for the safety function is cancelled, the drive restarts

automatically.
Ensure by external measures that the drive only starts after a confirmation

(EN 60204).