9400 HighLine | Parameter setting & configuration

TAs for positioning tasks

TA "Multi-purpose positioning" | Profile data management

396

Firmware 1.37 - 09/2006

L

13 Absolute CCW

The axis travels in CCW direction to an absolute position.

• Only possible with "modulo" traversing range

• Reference for the absolute position is zero position.

• In this direction the zero position of the axis can be overtravelled.

14 Absolute CCW TP

Like mode 13, but with profile change when a touch probe is detected.

Touch probe positioning

.

(C 397)

15 Absolute ShortestWay

The axis travels in best time to an absolute position.

• Only possible with "modulo" traversing range

• Reference for the absolute position is zero position.

• The rotary table positioning is basically an absolute positioning with target positions between 0 and 360

angular degree [°]. In this mode the zero point can also be overtravelled if this is the shortest way to the

target position:

16 Absolute ShortestWay TP

Like mode 15, but with profile change when a touch probe is detected.

Touch probe positioning

.

(C 397)

Positioning mode

360°/0°

60°

120°

300°

240°

180°