C02521, C02522, C02523 – Lenze E94AxHE Servo Drives 9400 HighLine (Firmware 01-37) User Manual

Page 615: C02524, C02525, C02526, Unit in, Is made in the unit defined in, And the feed constant, 9400 highline | parameter setting & configuration

Advertising
background image

L

Firmware 1.37 - 09/2006

615

9400 HighLine | Parameter setting & configuration

Parameter reference

Parameter list | C02521

C02521

C02522

C02523

C02524

C02525

C02526

Parameter | Name:

C02521 | Gearbox fact. denom. motor

Data type: INTEGER_32

Index: 22054

d

= 5626

h

Drive interface

Setting range

(min. value | unit | max. value)

Lenze setting

1

2147483647 1

;

Read access ; Write access ; CINH … PLC STOP … No transfer … COM … MOT

Parameter | Name:

C02522 | Gearbox fact. numer. load

Data type: INTEGER_32

Index: 22053

d

= 5625

h

Drive interface

Setting range

(min. value | unit | max. value)

Lenze setting

1

2147483647 1

;

Read access ; Write access ; CINH … PLC STOP … No transfer … COM … MOT

Parameter | Name:

C02523 | Gearbox fact. denom. load

Data type: INTEGER_32

Index: 22052

d

= 5624

h

Drive interface

Setting range

(min. value | unit | max. value)

Lenze setting

1

2147483647 1

;

Read access ; Write access ; CINH … PLC STOP … No transfer … COM … MOT

Parameter | Name:

C02524 | Feed constant

Data type: UNSIGNED_32

Index: 22051

d

= 5623

h

Drive interface

Setting range

(min. value | unit | max. value)

Lenze setting

0.0001

Unit/rev.

214748.3647 360.0000 Unit/rev.

;

Read access ; Write access ; CINH … PLC STOP … No transfer … COM … MOT Scaling factor: 10000

Parameter | Name:

C02525 | Unit

Data type: UNSIGNED_32

Index: 22050

d

= 5622

h

Drive interface

Selection list

(Lenze setting printed in bold)

Information

0 User-defined

The text entered in

C02526

is displayed for the unit.

1 Incr.
2 μm
3 mm
4 M
5 inch
6 yard
7 °

;

Read access ; Write access ; CINH … PLC STOP … No transfer … COM … MOT

Parameter | Name:

C02526 | User-defined unit

Data type: VISIBLE_STRING

Index: 22049

d

= 5621

h

User-defined unit which is displayed when

C02525

="0" is selected.

Drive interface

;

Read access ; Write access ; CINH … PLC STOP … No transfer … COM … MOT

Advertising