9400 HighLine | Parameter setting & configuration

TAs for interconnection via electrical shaft

Introduction | Transmission of the master angle

290

Firmware 1.37 - 09/2006

L

12.1.3

Transmission of the master angle

The master value/angle can be transmitted via the following transmission media:

r

Digital frequency

r

System bus (CAN)

r

ETHERNET Powerlink (in preparation)

The suitable bus medium is selected according to the criteria listed in the following

sections:

Digital frequency (simulation of an incremental encoder)

r

Rail or cascade structure is possible.

r

Only relative master value/master angle possible.

r

Max resolution 16 bits/revolution

r

Cable length is virtually unlimited but must not exceed 50 m from drive to drive.

r

Digital frequency extension module is required.

System bus (CAN)

r

No cascade structure possible.

r

Optionally absolute or relative master angle transfer possible.

r

Resolution up to 28 bits/revolution (in preparation; currently 16 bits/revolution).

r

Cable length is limited (dependent on baud rate, number of nodes and cable cross-

section).
– With a baud rate of 500 Kbit/s the total cable length is limited to e.g. 117 metres.

r

Interface of 9400 HighLine is already integrated.

System bus "CAN on board"

(C 134)

ETHERNET Powerlink (in preparation)

r

Rail or cascade structure is possible.

r

Optionally absolute or relative master angle transfer possible.

r

Resolution up to 28 bits/revolution.

r

Cable length is virtually unlimited but must not exceed 100 m from drive to drive.

r

Additional hardware (communication module ETHERNET Powerlink) is required.

Note!

For detailed information about the CANopen system bus interface, please see

the "CAN on-board 9400" Communication Manual.