Firmware 1.37 - 09/2006

247

9400 HighLine | Parameter setting & configuration

Standard TAs

TA "Actuator – speed" | Assignment of the I/O terminals

11.2.2.2

Actual value and status signals
The following tables contain the Lenze assignment of the analog and digital outputs for

the technology application "actuator – speed".

r

The default signal configuration if required can be easily changed by parameterising

the multiplexer parameters assigned.

Analog outputs

Digital outputs

State bus

Terminal X3

Signal (Lenze setting)

Signal configuration

AO1

Motor speed

• Scaling: ±10 V ≡ motor reference speed (

C00011

)

C03110/1

AO2

Motor torque (setpoint)

• Scaling: ±10 V ≡ Motor reference torque (

C00057/2

)

C03110/2

I/O terminals Analog outputs (C 120)

Terminal X4

Signal (Lenze setting)

Signal configuration

DO1

Status "Drive ready"

• This operating state is active if the controller is enabled by setting

the digital input RFR to HIGH level and no error has occurred.

C03100/1

DO2

Status "Speed follower enabled"

• The speed follower has been enabled via the digital input DI2.

C03100/2

DO3

Status "Speed follower in limitation"

• The enabled speed follower is in the limitation for more than

100 ms.

• The setpoint is limited to the upper or lower speed limit value

(

C00909/1

or

C00909/2

) .

C03100/3

DO4

Status "Error active acknowledgement is required"

• Monitoring with the error response "Error" or "Quick stop by

trouble" has been activated, and the controller is in the device

state "Error active" or "Quick stop by trouble active".

C03100/4

I/O terminals Digital outputs (C 125)

Terminal X2

Signal (Lenze setting)

Signal configuration

SB

Status "Speed follower in limitation"

• The enabled speed follower is in the limitation for more than

100 ms.

• The setpoint is limited to the upper or lower speed limit value

(

C00909/1

or

C00909/2

) .

• The state bus is put in the "error" status.

C03100/5

I/O terminals Monitoring function "State bus" (C 127)

GA

AO1

AO2

GO

24O

DO1

DO2

DO3

DO4

GE

24E

SB