Standard stop

The standard stop of the drive will be automatically activated by the internal state

machine if a basic function is deactivated and the drive is not yet in standstill.

r

The drive is braked to standstill via a parameterisable deceleration ramp.
– While the drive is braked to standstill, the state machine is in the function state

"Drive is stopped".

– If meanwhile another basic function is activated, this basic function takes over the

control of the drive from the current speed on and the function state "Drive is

stopped" is abandoned.

– If the drive is at standstill, it is automatically changed to the basic function "Drive in

standstill".

r

An acceleration phase active at the time of activating the stopping process is

considered by the standard stop, i.e. the current acceleration is at first led to "0" with

the parameterised S-ramp time before the real deceleration process starts.

r

If the controller is enabled while the shaft is coasting (controller inhibit and pulse

inhibit are deactivated), the drive is braked from the current speed to standstill.



Stop!

The basic functions "

Speed follower

", "

Torque follower

" and "

Position follower

"

take over the control of the drive not from the current speed on but with the

defined setpoint which may lead to a jerk!