1 integration into the application, 2 selecting the required safety module, 9400 highline | parameter setting & configuration – Lenze E94AxHE Servo Drives 9400 HighLine (Firmware 01-37) User Manual

Page 136

Advertising
background image

9400 HighLine | Parameter setting & configuration

Safety engineering

Integration into the application

136

Firmware 1.37 - 09/2006

L

8.1

Integration into the application

If a safety function is required, the safety engineering activates a corresponding safe

monitoring function. The standstill function, however, is only executed directly in case of

the function "Safe torque off" (STO). In case of the other safety functions an action of the

controller is required, which is safely monitored. The implementation of the corresponding

action (e.g. braking, braking to standstill, holding of the standstill position) must be carried

out by the application.

"LS_SafetyModule" system block
For the transmission of the control and status information from the safety module to the

application the LS_SafetyModule system block is provided in the function block editor of

the »Engineers«.

Basic function "Limiter"
Furthermore the LS_Limiter system block which contains the basic function

Limiter

" is

provided in the function block editor for the connection of safety engineering to the

application.

(C 200)

The basic function "Limiter" provides a parameter setting surface in the »Engineer« for a

comfortable setting of limit positions, limited speeds and limit values and enables the

drive to braked selectively after request through the safety module.

General procedure

1. Activation of the safety function on the safety module (e. g. SS1 - safe stop 1).



Monitoring starts.

2. The safety module informs the controller via a control word that the safety function

has been activated.

3. The application evaluates the control word and starts the required motion sequence

(e.g. braking).

8.2

Selecting the required safety module

The safety module expected by the application and the controller is selected in

C00214

.

r

In the »Engineer« this setting is carried out automatically by assigning the device

module to the controller, i.e., the »Engineer« sets

C00214

automatically according to

the safety module selected.

r

If the safety module selected in

C00214

does not correspond to the safety module type

connected, an error will be activated.

Advertising