9400 HighLine | Parameter setting & configuration

TAs for interconnection via electrical shaft

TA "Electronic gearbox" | Selection of master value source and output

12.2.4.2

Master value source: Digital frequency input
To use the digital frequency input as master value source, the controller must be provided

with digital frequency extension module (E94AYFLF).
To ensure the integration of the extension module in the application, the TA "Electronic

gearbox" must be used as technology application.

O

Tip!
Detailed information on the digital frequency extension module can be found in

the User Manual "Digital frequency extension module (E94AYFLF) – parameter

setting & configuration".

12.2.4.3

Master value source: Bus system
When the master value is selected via a bus system as e.g. system bus (CAN) it is possible

to first extrapolate the received position information to compensate higher bus

transmission cycles.

r

Parameter setting: Tab Application parameter  Dialog level Overview  Electronic

gearbox  Master value extrapolation

r

Configuration: Tab FB editor  FB MotionBusIn

Note!

The technology application "Electronic gearbox" MotionBus" which can also be

selected in the application catalog does not contain any interfaces to the digital

frequency extension module.

Parameters

Lenze setting

Value Unit

C03550

Number of extrapolation cycles

1

Control inputs of the function

Signal configuration

Lenze setting

Control input

(Multiplexer parameters)

TRUE  Activate extrapolation

C03058/9