Firmware 1.37 - 09/2006

L

Use of further ramp parameter sets
If required, 15 further ramp parameter sets can be parameterised. For the selection of the

ramp parameter sets1 ... 15 the selection inputs are to be assigned with the corresponding

signals. The selection of the ramp parameter sets is carried out in a binary coded manner.

r

Parameter setting: Tab Application parameter Dialog levelOverview  Ramp

generator  All ramp parameters

Parameters

Lenze setting

Value Unit

C03512/1

Acceleration time 1

0.000 s

C03512/...

Acceleration time ...

... ...

C03512/15

Acceleration time 15

0.000 s

C03513/1

Deceleration time 1

0.000 s

C03513/...

Deceleration time ...

... ...

C03513/15

Deceleration time 15

0.000 s

C03514/1

S-ramp time 1

0.000 s

C03514/...

S-ramp time

... ...

C03514/15

S-ramp time 15

0.000 s

Control inputs of the function

Signal configuration

Lenze setting

Control input

(Multiplexer parameters)

FALSE  Activate ramp parameter set 1

C03009/8

FALSE  Activate ramp parameter set 2

C03009/9

FALSE  Activate ramp parameter set 4

C03009/10

FALSE  Activate ramp parameter set 8 a

C03009/11