Encoder evaluation

Parameter setting

110

Firmware 1.37 - 09/2006

L

6.2

Parameter setting

Short overview of parameters for the encoder evaluation:

See also:

Parameterise motor encoder

(C 70)

Parameter

Information

Lenze setting

Value Unit

C00058/1

Rotor displ. angle of resolver

-90.0 °

C00058/2

Rotor displ. angle of encoder

0.0 °

C00058/3

Rotor displ. angle of module

0.0 °

C00080

Resolver pole pair number

1

C00420

Encoder PPR

512

C00421

Encoder voltage

5.0 V

C00422

Encoder type

Incremental encoder (TTL signal)

C00490

Position encoder

Motor encoder

C00495

Motor encoder

Resolver X7

C00497

Speed act. val. time const.

0.4 ms

C00579

Resp. to speed monitoring

Off

C00580

Resp. to encoder open circuit

Fault

C00586

Resp. to resolver open circuit

Fault

C00601

Resp. to encoder error

Fault

C02527

Motor mounting direction

Motor rotating clockwise

C02529

Mounting direction of position encoder

Motor rotating counter-clockwise

C02570

Controller configuration

Phase control

C02572

Speed setpoint

- Unit/s

C02573

Position setpoint

- Unit

C02574

Actual speed

- Unit/s

C02575

Actual position

- Unit

C02576

Following error

- Unit

C02577

External actual position

- Unit

C02578

Offset - actual position value/position setpoint

- Unit

Highlighted in grey = display parameter