Maximum speed has been exceeded [0x00b80010, Maximum acceleration has been exceeded [0x00b80011, 9400 highline | parameter setting & configuration – Lenze E94AxHE Servo Drives 9400 HighLine (Firmware 01-37) User Manual

Page 536

Advertising
background image

9400 HighLine | Parameter setting & configuration

Diagnostics & error analysis

Error messages of the operating system

536

Firmware 1.37 - 09/2006

L

Maximum speed has been exceeded [0x00b80010]

Maximum acceleration has been exceeded [0x00b80011]

Response (Lenze setting printed in bold)

Setting:

C02716/3

(; Adjustable response)

:

None … System fault ; Fault ; Trouble ; Quick stop by trouble ; Warning locked ; Warning ; Information

Cause

Remedy

The max. speed parameterised in

C02703

has been

exceeded.

• Reduce speed.

• Increase maximum speed (

C02703

).

• Deactivate monitoring of the limit values by the basic

function "Limiter".

Response (Lenze setting printed in bold)

Setting:

C02716/3

(; Adjustable response)

:

None … System fault ; Fault ; Trouble ; Quick stop by trouble ; Warning locked ; Warning ; Information

Cause

Remedy

The max. acceleration parameterised in

C02705

has

been exceeded.

• Reduce acceleration.

• Increase maximum acceleration (

C02705

).

• Deactivate monitoring of the limit values by the basic

function "Limiter".