Basic drive functions

Homing | Parameter setting

9.5.1

Parameter setting

r

Parameterisation dialog in the »Engineer«: Tab Application parameter  dialog level

Overview  All basic functions  Homing

r

Short overview of the parameters for homing:

9.5.1.1

Homing mode
The zero position, also called reference, can be defined by a reference search or reference

setting:

r

In case of a reference search the drive travels according to a defined mode to detect the

reference independently.

r

In case of reference setting the reference is manually set when the drive has stopped.

O

Tip!
A reference search is mainly used for continuous systems or if the traversing range

or machine cycle of the drive cannot be displayed in the display space of the

encoder, e.g. when incremental encoders are used on a motor or single-turn

absolute value encoders or resolvers on geared motors.
Reference setting is usually executed only once during commissioning or in case of

service (e.g. when drive components are exchanged) and are normally used in

systems the machine cycle of which can be displayed in the display space of the

encoder, e.g. when multi-turn absolute value encoder or single-turn absolute value

encoders/resolvers are used in a machine cycle on one motor revolution.

Parameters

Information

C02528

Traversing range

C02640

Ref. mode

C02642

HM position

C02643

HM target position

C02644

Ref. speed 1

C02645

Home acceleration 1

C02646

Ref. speed 2

C02647

Ref. acceleration 2

C02648

Home S-ramp time

C02649

HM torque limit

C02650

Homing inhibit time

C02651

HM touch probe configuration

C02652

Home position after mains switching

C02653

Max. rot. angle after mains sw.

C02656

Current position