8 manual jog, 9400 highline | parameter setting & configuration – Lenze E94AxHE Servo Drives 9400 HighLine (Firmware 01-37) User Manual

Page 401

Advertising
background image

L

Firmware 1.37 - 09/2006

401

9400 HighLine | Parameter setting & configuration

TAs for positioning tasks

TA "Multi-purpose positioning" | Manual jog

13.2.8

Manual jog

[13-14] Basic function "Manual jog" (schematic diagram)

r

Parameter setting: Tab Application parameter  Dialog level Overview  Manual jog

O

Tip!
Detailed information on the manual jog function can be found in chapter "Basic

drive functions"  subchapter "

Manual jog

".

(C 156)

For the setting-up operation and

"Teaching" of positions the basic function

"Manual jog" is available.
Manual jog is controlled via parameters

(e. g. via HMI).
Manual jog can always be carried out if the

sequence control is not active abd no other

basic function and no error status are

active. The request of manual jog then is

effected automatically with the travel

commands.

LS_ManualJog

n

t

и

з

LS_Brake

n

t

LS_Limiter

n

t

LS_Quickstop

STOP

n

t

LS_Stop

internal
status machine

Status

machine

(basic drive

functions)

Basic drive functions

M

0

-100

100 200

LS_Homing

n

t

LS_Positioner

Parameters

Lenze setting

Value Unit

C02620

Manual jog speed 1

360.0000 Unit/s

C02621

Manual jog speed 2

720.0000 Unit/s

C02622

Manual acceleration

360.0000 Unit/s

2

C02623

Manual deceleration

1440.0000 Unit/s

2

C02624

Inaccuracy time of manual traversing

0.100 s

C03007

Activate positive manual jog

FALSE

C03008

Activate negative manual jog

FALSE

C03009

Activate "Retract limit switch"

FALSE

Control inputs of the function

Signal configuration

Lenze setting

Control input

(Multiplexer parameters)

Automatic

activation



Request manual jog

C03155/1

C03007  Activate positive manual jog

C03155/2

C03008  Activate negative manual jog

C03155/3

FALSE  Activate 2. speed

C03155/4

C03009  Activate "Retract limit switch"

C03155/5

Advertising