4 operation, 1 selecting the variables to be recorded – Lenze E94AxHE Servo Drives 9400 HighLine (Firmware 01-37) User Manual

Page 421

Advertising
background image

L

Firmware 1.37 - 09/2006

421

9400 HighLine | Parameter setting & configuration

Oscilloscope

Operation

14.4

Operation

This chapter describes step-by-step how to record the signal characteristics of controller

variables and represent, analyse, document and process them in the oscilloscope.

14.4.1

Selecting the variables to be recorded

The oscilloscope supports up to eight channels, i.e. max. eight variables can be recorded in

a data record. Use the Vertical group box to select the variables.

M

How to select a variable for recording:

1. Go to the Variable column in the Vertical group box and double-click in the yellow

field to open the Select variable dialog box.
• The dialog box lists all variables declared in the PLC program of the controller

and the system variables of the internal motor (MCTRL).

2. Select the variable to be recorded from the list field.
3. Click OK.

• The dialog box is closed and the selection is accepted.

4. Repeat steps 1 ... 3 to select up to seven more variables to be recorded.

Of course, it is any time possible to change or delete a selection later.

M

How to change a selection:

1. Go to the Vertical group box and double-click the variable to be changed in the

Variable column.

2. Select a new variable in the Select variable dialog box.
3. Click OK.

• The dialog box is closed and the selection is accepted.

Note!

In the oscilloscope, settings can only be selected and recording can only be

started, when the controller is connected online.

Advertising