Firmware 1.37 - 09/2006

L

C00356

C00357

C00359

Parameter | Name:

C00356 | CAN TPDOx cycle time

Data type: UNSIGNED_16

Index: 24219

d

= 5E9B

h

TPDO event time from DS301V402.

• With a value unequal "0", the TPDO will be sent after the set time without considering the transmission type.
Setting range

(min. value | unit | max. value)

0

ms

65535

Subcodes

Lenze setting

Information

C00356/1

0 ms

Cycle time for TPDO1 ... TPDO4

C00356/...
C00356/4

;

Read access ; Write access … CINH … PLC STOP … No transfer … COM … MOT

Parameter | Name:

C00357 | CAN RPDOx monitoring time

Data type: UNSIGNED_16

Index: 24218

d

= 5E9A

h

RPDO event time from DS301V402.

• With a value unequal "0", the RPDO will be expected after the set time.

• If the RPDO is not received within this time, a parameterisable error message can be activated.
Setting range

(min. value | unit | max. value)

0

ms

65535

Subcodes

Lenze setting

Information

C00357/1

3000 ms

Monitoring time for RPDO1 ... RPDO4

C00357/...
C00357/4

;

Read access ; Write access … CINH … PLC STOP … No transfer … COM … MOT

Parameter | Name:

C00359 | CAN status

Data type: UNSIGNED_8

Index: 24216

d

= 5E98

h

Selection list

(display only)

0 Operational
1 Pre-operational
4 Boot up
5 Stopped
7 Reset
8 INITIALISATION
9 Unknown

10 Autom. baud rate detection active

;

Read access … Write access … CINH … PLC STOP … No transfer … COM … MOT