C02549, C02550, C02552 – Lenze E94AxHE Servo Drives 9400 HighLine (Firmware 01-37) User Manual

Page 620: C02549/1, C02549/4, C02549/6, C02549/7, C02549/8, C02549/9, C02549/10

Advertising
background image

9400 HighLine | Parameter setting & configuration

Parameter reference

Parameter list | C02549

620

Firmware 1.37 - 09/2006

L

C02549

C02550

C02552

Parameter | Name:

C02549 | Drive interface: Signals

Data type: UNSIGNED_32

Index: 22026

d

= 560A

h

Display of the boolean signals of the

drive interface

(LS_DriveInterface).

Selection list

0 FALSE
1 TRUE

Subcodes

Information

C02549/1

DI_bSetCInh

C02549/2

Reserved

C02549/3

Reserved

C02549/4

DI_bSwitchOn

C02549/5

Reserved

C02549/6

DI_bReady

C02549/7

DI_bFailActive

C02549/8

DI_bImpActive

C02549/9

DI_bCInhActive

C02549/10

DI_bWarningActive

C02549/11

DI_bUVDetected

C02549/12

DI_bOVDetected

C02549/13

DI_bMainSupplyOk

C02549/14

DI_bReadyToSwitchOn

C02549/15

DI_bOperationEnabled

;

Read access … Write access … CINH … PLC STOP … No transfer … COM … MOT

Parameter | Name:

C02550 | Setpoint interpolation

Data type: UNSIGNED_32

Index: 22025

d

= 5609

h

Motor interface

Selection list

0 Off
1 ON

Subcodes

Lenze setting

Information

C02550/1

0: Off

Position setpoint interpolat.

C02550/2

0: Off

Speed setpoint interpolat.

C02550/3

0: Off

Torque setpoint interpolat.

;

Read access ; Write access … CINH … PLC STOP … No transfer … COM … MOT

Parameter | Name:

C02552 | Position setpoint

Data type: INTEGER_32

Index: 22023

d

= 5607

h

Motor interface

Display range

(min. value | unit | max. value)

-214748.3647

Unit

214748.3647

;

Read access … Write access … CINH … PLC STOP … No transfer … COM … MOT Scaling factor: 10000