7 "manual jog" mode, 9400 highline | parameter setting & configuration – Lenze E94AxHE Servo Drives 9400 HighLine (Firmware 01-37) User Manual

Page 315

Advertising
background image

L

Firmware 1.37 - 09/2006

315

9400 HighLine | Parameter setting & configuration

TAs for interconnection via electrical shaft

TA "Electronic gearbox" | "Manual jog" mode

12.2.7

"Manual jog" mode

In the "Manual jog" mode (C03006 = "4") the drive is decoupled from the electrical shaft

and the basic function "Manual jog" is enabled:

[12-18] "Manual jog" mode (schematic diagram)

r

Parameter setting: Tab Application parameter  Dialog level Overview  Manual jog

O

Tip!
Detailed information on the manual jog function can be found in chapter "Basic

drive functions"  subchapter "

Manual jog

".

(C 156)

v

t

LS_ManualJog

n

t

и

з

n

t

LS_Positioner

0

-100

100 200

LS_Homing

C03006 = 4

t

M

Slave

Parameters

Lenze setting

Value Unit

C02620

Manual jog speed 1

360.0000 Unit/s

C02621

Manual jog speed 2

720.0000 Unit/s

C02622

Manual acceleration

360.0000 Unit/s

2

C02623

Manual deceleration

1440.0000 Unit/s

2

C02624

Inaccuracy time of manual traversing

0.100 s

C03007

Positive manual jog

Inactive

C03008

Negative manual jog

Inactive

Control inputs of the function

Signal configuration

Lenze setting

Control input

(Multiplexer parameters)

C03007  Activate positive manual jog

C03155/2

C03008  Activate negative manual jog

C03155/3

FALSE  Activate 2. speed

C03155/4

FALSE  Retract limit switch

C03155/5

Advertising