9400 HighLine | Parameter setting & configuration

Parameter reference

Parameter list | C00806

604

Firmware 1.37 - 09/2006

L

C00806

C00807

C00808

C00809

C00810

C00811

Parameter | Name:

C00806 | MCTRL_dnTorqueLowLimit

Data type: INTEGER_32

Index: 23769

d

= 5CD9

h

Internal motor control (MCTRL) signal
Display range

(min. value | unit | max. value)

-21474836.47

Nm

21474836.47

;

Read access … Write access … CINH … PLC STOP … No transfer … COM … MOT Scaling factor: 100

Parameter | Name:

C00807 | MCTRL_dnTorqueHighLimit

Data type: INTEGER_32

Index: 23768

d

= 5CD8

h

Internal motor control (MCTRL) signal
Display range

(min. value | unit | max. value)

-21474836.47

Nm

21474836.47

;

Read access … Write access … CINH … PLC STOP … No transfer … COM … MOT Scaling factor: 100

Parameter | Name:

C00808 | MCTRL_dnPosCtrlOutLimit

Data type: INTEGER_32

Index: 23767

d

= 5CD7

h

Internal motor control (MCTRL) signal
Display range

(min. value | unit | max. value)

-480000

rpm

480000

;

Read access … Write access … CINH … PLC STOP … No transfer … COM … MOT

Parameter | Name:

C00809 | MCTRL_dnTorqueCtrlAdapt

Data type: INTEGER_32

Index: 23766

d

= 5CD6

h

Internal motor control (MCTRL) signal
Display range

(min. value | unit | max. value)

-200.00

%

200.00

;

Read access … Write access … CINH … PLC STOP … No transfer … COM … MOT Scaling factor: 100

Parameter | Name:

C00810 | MCTRL_dnSpeedCtrlAdapt

Data type: INTEGER_32

Index: 23765

d

= 5CD5

h

Internal motor control (MCTRL) signal
Display range

(min. value | unit | max. value)

-200.00

%

200.00

;

Read access … Write access … CINH … PLC STOP … No transfer … COM … MOT Scaling factor: 100

Parameter | Name:

C00811 | MCTRL_dnPosCtrlAdapt

Data type: INTEGER_32

Index: 23764

d

= 5CD4

h

Internal motor control (MCTRL) signal
Display range

(min. value | unit | max. value)

-200.00

%

200.00

;

Read access … Write access … CINH … PLC STOP … No transfer … COM … MOT Scaling factor: 100