9400 highline | parameter setting & configuration, Outputs – Lenze E94AxHE Servo Drives 9400 HighLine (Firmware 01-37) User Manual

Page 181

Advertising
background image

L

Firmware 1.37 - 09/2006

181

9400 HighLine | Parameter setting & configuration

Basic drive functions

Positioning | System block "LS_Positioner"

Outputs

POS_dnSpeedOverride_n

C02677/1

| DINT

Value of speed override

• Percentage multiplier for the current profile parameter "Speed".

• Changes are accepted in each cycle.

• 2

30

≡ 100 % of the speed defined in the profile.

• In case of values ≤ 1 % the status bit 18 is set.

• Values ≤ 0 % are set internally to 0 % and let the drive be braked to standstill.

POS_dnAccOverride_n

C02677/2

| DINT

Value for acceleration override

• Percentage multiplier for the current profile parameter "Acceleration".

• Changes are accepted in each cycle.

• 2

30

≡ 100 % of the acceleration defined in the profile.

• In case of values ≤ 1 % the status bit 19 is set.

• Values ≤ 0 % are set internally to 0 % ("no acceleration").

POS_bDisableTP

C02679/6

| BOOL

Deactivating touch probe positioning

TRUE Identified touch probes are ignored. It is not automatically changed

to the TP sequence profile defined in the profile data.

Identifier

DIS code | data type

Value/meaning

POS_dnState

C02675

| DINT

Status (bit-coded)

• When the basic function is not enabled, all bits are set to "0".

• Bits which are not listed are not assigned with a status (always "0").

Bit 1 Positioning is active.
Bit 2 Positioning is completed (all profiles are executed).
Bit 3 Acceleration/deceleration phase is active.
Bit 5 CCW rotation is active.
Bit 6 Set position reached (in case of sequence profiles the drive continues

to travel).

Bit 10 Zero crossing in the positioning mode "modulo".
Bit 15 Error in basic function active (group signal).
Bit 16 Positioning is aborted.
Bit 17 Reversing phase is active.
Bit 18 Speed override ≤1 %
Bit 19 Acceleration override ≤1 %
Bit 20 Position is limited by basic function "

Limiter

".

Bit 21 Profile data are limited by basic function "

Limiter

".

Bit 22 Direction is inhibited by basic function "

Limiter

".

Bit 23 Abort by basic function "

Limiter

".

Bit 24 Home position is not known.
Bit 25 Stopping is active.
Bit 26 Cycle is not known.
Bit 27 Invalid positioning mode.
Bit 28 Invalid change of the positioning mode.
Bit 29 Profile data is not plausible or faulty.
Bit 30 Profile generation error.

Identifier

DIS code | data type

Information/possible settings

Advertising