C00779, C00780, C00781 – Lenze E94AxHE Servo Drives 9400 HighLine (Firmware 01-37) User Manual

Page 601: C00782, C00783, C00784, Ay in, In [a, 9400 highline | parameter setting & configuration

Advertising
background image

L

Firmware 1.37 - 09/2006

601

9400 HighLine | Parameter setting & configuration

Parameter reference

Parameter list | C00779

C00779

C00780

C00781

C00782

C00783

C00784

Parameter | Name:

C00779 | MCTRL_dnDCBusVoltage

Data type: INTEGER_32

Index: 23796

d

= 5CF4

h

Internal motor control (MCTRL) signal
Display range

(min. value | unit | max. value)

0

V

1000

;

Read access … Write access … CINH … PLC STOP … No transfer … COM … MOT

Parameter | Name:

C00780 | MCTRL_dnImotAct

Data type: INTEGER_32

Index: 23795

d

= 5CF3

h

Internal motor control (MCTRL) signal
Display range

(min. value | unit | max. value)

-500.00

A

500.00

;

Read access … Write access … CINH … PLC STOP … No transfer … COM … MOT Scaling factor: 100

Parameter | Name:

C00781 | MCTRL_dwMaxMotorSpeed

Data type: UNSIGNED_32

Index: 23794

d

= 5CF2

h

Internal motor control (MCTRL) signal
Display range

(min. value | unit | max. value)

0

rpm

480000

;

Read access … Write access … CINH … PLC STOP … No transfer … COM … MOT

Parameter | Name:

C00782 | MCTRL_dwMaxMotorTorque

Data type: UNSIGNED_32

Index: 23793

d

= 5CF1

h

Internal motor control (MCTRL) signal
Display range

(min. value | unit | max. value)

0.000

Nm

2147483.647

;

Read access … Write access … CINH … PLC STOP … No transfer … COM … MOT Scaling factor: 1000

Parameter | Name:

C00783 | MCTRL_dwMotorVoltageAct

Data type: UNSIGNED_32

Index: 23792

d

= 5CF0

h

Internal motor control (MCTRL) signal
Display range

(min. value | unit | max. value)

0

V

2000

;

Read access … Write access … CINH … PLC STOP … No transfer … COM … MOT

Parameter | Name:

C00784 | MCTRL_dnMotorFreqAct

Data type: INTEGER_32

Index: 23791

d

= 5CEF

h

Internal motor control (MCTRL) signal
Display range

(min. value | unit | max. value)

-800.0

Hz

800.0

;

Read access … Write access … CINH … PLC STOP … No transfer … COM … MOT Scaling factor: 10

Advertising