9400 HighLine | Parameter setting & configuration

Parameter reference

Parameter list | C00005

C00005

C00006

C00007

C00011

C00018

C00019

Parameter | Name:

C00005 | Application selection

Data type: INTEGER_32

Index: 24570

d

= 5FFA

h

Application selection

• Use the controller command

C00002

="5" to activate the selected application.

Setting range

(min. value | unit | max. value)

Lenze setting

-1

16 0

;

Read access ; Write access … CINH … PLC STOP ; No transfer … COM … MOT

Parameter | Name:

C00006 | Motor control selection

Data type: UNSIGNED_32

Index: 24569

d

= 5FF9

h

Selection list

(Lenze setting printed in bold)

Information

1 Servo control with SM

For synchronous motors with speed sensor

2 Servo controller with ASM

For asynchronous motors with speed sensor

;

Read access ; Write access ; CINH … PLC STOP … No transfer … COM ; MOT

Parameter | Name:

C00007 | Active application

Data type: UNSIGNED_32

Index: 24568

d

= 5FF8

h

Display range

(min. value | unit | max. value)

0

4294967295

;

Read access … Write access … CINH … PLC STOP … No transfer … COM … MOT

Parameter | Name:

C00011 | Motor reference speed

Data type: UNSIGNED_32

Index: 24564

d

= 5FF4

h

For parameter setting via interface: In case of bigger changes, only change the setting in one step when the

controller is inhibited!
Setting range

(min. value | unit | max. value)

Lenze setting

50

rpm

50000 3000 rpm

;

Read access ; Write access … CINH … PLC STOP … No transfer … COM ; MOT

Parameter | Name:

C00018 | Chopper frequency

Data type: UNSIGNED_32

Index: 24557

d

= 5FED

h

Selection list

(Lenze setting printed in bold)

Information

2 1 kHz fixed

Note:

The maximum output frequency of the controller is

limited to 1/8 of the switching frequency selected here!

3 2 kHz fixed
4 4 kHz fixed
5 8 kHz fixed
8 2 kHz variable
9 4 kHz variable

10 8 kHz variable
11 16 kHz variable

;

Read access ; Write access … CINH … PLC STOP … No transfer … COM ; MOT

Parameter | Name:

C00019 | Zero speed detection threshold

Data type: UNSIGNED_32

Index: 24556

d

= 5FEC

h

Setting range

(min. value | unit | max. value)

Lenze setting

0

rpm

450 5 rpm

;

Read access ; Write access … CINH … PLC STOP … No transfer … COM … MOT