2 speed ramp generator, 9400 highline | parameter setting & configuration – Lenze E94AxHE Servo Drives 9400 HighLine (Firmware 01-37) User Manual

Page 275

Advertising
background image

L

Firmware 1.37 - 09/2006

275

9400 HighLine | Parameter setting & configuration

Standard TAs

TA "Actuator – torque" | Speed limit value conditioning

11.3.5.2

Speed ramp generator

[11-19] Ramp generator (schematic diagram)

In order to avoid setpoint step-changes the speed limit value passes a ramp generator with

a parameterisable acceleration and deceleration time before it is transmitted to the basic

drive function "Torque follower".

r

Parameter setting: Tab Application parameter  Dialog level Overview

Offset

Selection

LS_Torque...

M

Torque
setpoint

DI2

DI4

OUT

IN

Ramp generator

%

1

%

2

%

15

Fixed setpoints

Status

machine

(basic drive

functions)

Speed limit

AIN2

M

v

F

Parameters

Lenze setting

Value Unit

C03502

Basic acceleration time

1.000 s

C03503

Basic deceleration time

1.000 s

C03510

Profile mode

Linear ramps

Advertising