L

Firmware 1.37 - 09/2006

23

9400 HighLine | Parameter setting & configuration

Introduction

Communicating with the controller

4. Click Find controller path to find the controller in the selected bus system.

• The Address assignment dialog box appears:

5. Select the corresponding controller from the Identified field devices list field.
6. Click OK.

• The Address assignment dialog box is closed and the selected Controller access

path (e.g. "DDCMP:/") is indicated in the Assignment of offline controllers dialog

box.

7. Click Connect.

• The dialog box is closed and the online connection with the controller is built up.
• In the Project view, a yellow icon indicates the online connection with the

controller:

Now you can use the icons and to easily build up and end a connection with the

controller. The communication settings are only required when communication with a

controller is built up for the first time.

r

If you want to change the existing configuration, select the command OnlineGo

online to open the Assignment of offline controllers dialog box and change the settings.

r

With an online connection, the »Engineer« displays the current parameter settings of

the controller with a yellow background colour.



Stop!

If you change parameters in the »Engineer« while the controller is connected

online, the changes will be directly accepted by the controller!