C01902, C01903, C01905 – Lenze E94AxHE Servo Drives 9400 HighLine (Firmware 01-37) User Manual

Page 613: C02104, C02108, 9400 highline | parameter setting & configuration

Advertising
background image

L

Firmware 1.37 - 09/2006

613

9400 HighLine | Parameter setting & configuration

Parameter reference

Parameter list | C01902

C01902

C01903

C01905

C02104

C02108

Parameter | Name:

C01902 | Diagnostics X6: Max. baud rate

Data type: UNSIGNED_32

Index: 22673

d

= 5891

h

Maximum permissible baud rate of the basic device after determination of the baud rate at the diagnostics

interface X6

• Communication starts with the default baud rate 19200 of the basic device.
Selection list

(Lenze setting printed in bold)

9600 9600 baud

19200 19.200 baud
38400 38.400 baud
57600 57.600 baud

115200 115.200 baud
230400 230.400 baud
375000 375.000 baud
750000 750.000 baud

1500000 1.500.000 baud
3000000 3.000.000 baud

;

Read access ; Write access … CINH … PLC STOP … No transfer ; COM … MOT

Parameter | Name:

C01903 | Diagnostics X6: Change baud rate

Data type: UNSIGNED_32

Index: 22672

d

= 5890

h

New Determination of the baud rate at the diagnostics interface X6
Selection list

(Lenze setting printed in bold)

0 Ignore changes
1 Set a higher baud rate

;

Read access ; Write access … CINH … PLC STOP ; No transfer … COM … MOT

Parameter | Name:

C01905 | Diagnostics X6: Curr. baud rate

Data type: UNSIGNED_32

Index: 22670

d

= 588E

h

Current baud rate at diagnostics interface X6
Display range

(min. value | unit | max. value)

0

3000000

;

Read access … Write access … CINH … PLC STOP … No transfer … COM … MOT

Parameter | Name:

C02104 | Program auto-start

Data type: UNSIGNED_32

Index: 22471

d

= 57C7

h

Selection list

(Lenze setting printed in bold)

0 Off
1 Autom. after mains connection

;

Read access ; Write access … CINH … PLC STOP … No transfer … COM … MOT

Parameter | Name:

C02108 | Program status

Data type: UNSIGNED_8

Index: 22467

d

= 57C3

h

Selection list

(display only)

0 Program is running
1 Program stopped
2 Program stopped at breakpoint

;

Read access … Write access … CINH … PLC STOP … No transfer … COM … MOT

Advertising