9400 HighLine | Parameter setting & configuration

Basic drive functions

Homing | Parameter setting

9.5.1.2

Home position & target position
When the home position is set during the reference search, the position detected in the

machine measuring system corresponds to the value set in

C02642

.

Afterwards the drive travels to the target position set in

C02643

.

Operation of mode 14:

1. Movement in positive direction with reduced

torque.

2. The reference is set if the torque limit has

been exceeded via a defined period of time

("homing to end stop").
– If a reference offset is set, it is traversed by

this offset with the correct sign and the

reference is set at the end of this travel

way.

Operation of mode 15:

1. Movement in negative direction with

reduced torque.

2. The reference is set if the torque limit has

been exceeded via a defined period of time

("homing to end stop").
– If a reference offset is set, it is traversed by

this offset with the correct sign and the

reference is set at the end of this travel

way.

Reference position

Reference position