Read the motor data out of the controller

If the Lenze motor connected to the controller has an electronic nameplate (ENP), the

motor does not need to be selected in the »Engineer« motor catalog.

r

When the controller is switched on initially, all motor data are automatically read out

of the electronic motor nameplate and stored at first temporarily in the controller.

r

For a permanent acceptance of the motor data, the parameter set must be saved

(

C00002

= "11").

r

If there is an online connection between the »Engineer« and the controller, the motor

data of the controller can be taken over into the »Engineer« project.

M

How to read the motor data out of the controller:

1. Establish an online connection between »Engineer« and controller.
2. Go to the Application parameter tab and change to the dialog level

OverviewMotor.

3. Press the out of controller button.

• Then the motor data are read out of the controller and directly written into the

corresponding codes of the »Engineer« project.

5.1.2

Select motor in the »Engineer« motor catalog

If the Lenze motor does not have an electronic nameplate (ENP) or if a motor of a third-

party manufacturer is used, select the motor in the »Engineer« via the motor catalog and

transfer the motor data to the controller.

r

If you, when inserting the controller into the project in the dialog step "Other

components" put a checkmark in the control field Motor, you can select as a further

dialog step the motor for the controller from the motor catalog.

r

As an alternative you can also insert the motor at a later date into the project via the

command Insert component.

O

Tip!
If you use a motor of a third-party manufacturer, you can at first select a suitable

motor concerning the rated data for current, voltage and speed and then adapt the

motor data exactly to the existing motor.

Display/edit motor data in the »Engineer«

(C 67)