3 system block "ls_digitaloutput, 9400 highline | parameter setting & configuration, I/o terminals digital outputs – Lenze E94AxHE Servo Drives 9400 HighLine (Firmware 01-37) User Manual

Page 126

Advertising
background image

9400 HighLine | Parameter setting & configuration

I/O terminals

Digital outputs

126

Firmware 1.37 - 09/2006

L

7.5.3

System block "LS_DigitalOutput"

The system block LS_DigitalOutput displays the interface to the digital outputs, the state

bus and the yellow user LED on the front of the controller in the function block editor.

Input

DIS code | Data type

Information/possible settings

DIGOUT_bOut1

C00444/1

| BOOL

...

DIGOUT_bOut4

C00444/4

| BOOL

Digital outputs 1 ... 4

DIGOUT_bStateBusOut

C00444/18

| BOOL

Setting the state bus to the status "Error"

Monitoring function "State bus" (C 127)

TRUE The state bus is set to LOW level, all devices connected to the state

bus start their pre-programmed response.

DIGOUT_bUserLED

C00444/9

| BOOL

Control of yellow user LED on the front of the controller

TRUE LED on

GO

24O

DO1

DO2

DO3

DO4

LS_DigitalOutput

DIGOUT_bOut1

DIGOUT_bStateBusOut

DIGOUT_bOut3

DIGOUT_bOut2

X4

1

0

1

C00118/1...4

DIGOUT_bOut4

DIGOUT_bUserLED

User LED

C00444/1...4

GE