9400 HighLine | Parameter setting & configuration

Basic drive functions

General information | Requesting control via a basic function

Re-deactivation the enable of a basic function
When the enable input bEnable of the active basic function is reset to FALSE, the control

inputs of the basic function are inhibited and the status outputs bEnabled, bActive and

bDone are reset to FALSE.

r

When the drive is not at standstill, it is decelerated to standstill within the deceleration

time for

Standard stop

unless another basic function takes over the control of the drive.

Here, the active function state is changed to the basic state "Drive in standstill" via the

function state "Drive is stopped".

r

When the enable input of another basic function is set to TRUE, this basic function

adopts the control of the drive immediately.