9400 HighLine | Parameter setting & configuration

TAs for interconnection via electrical shaft

TA "Synchronism with mark synchronisation" | Assignment of the I/O terminals

336

Firmware 1.37 - 09/2006

L

12.3.2.2

Actual value and status signals
The following tables contain the Lenze assignment of the analog and digital outputs for

the technology application "Synchronism".

r

The default signal configuration if required can be easily changed by parameterising

the multiplexer parameters assigned.

Analog outputs

Digital outputs

State bus

Display elements

Terminal X3

Signal (Lenze setting)

Signal configuration

AO1

Motor speed

• Scaling: ±10 V ≡ motor reference speed (

C00011

)

C03110/1

AO2

Motor torque (setpoint)

• Scaling: ±10 V ≡ Motor reference torque (

C00057/2

)

C03110/2

I/O terminals Analog outputs (C 120)

Terminal X4

Signal (Lenze setting)

Signal configuration

DO1

Status "Drive ready"

• This operating state is active if the controller is enabled by setting

the digital input RFR to HIGH level and no error has occurred.

C03100/1

DO2

Status "Electrical shaft enabled"

C03100/2

DO3

Status "Limitation active"

• A setpoint is limited at the moment.

C03100/3

DO4

"Error" status

• If the controller is in the error state, the digital output DO4 is set

to HIGH level.

C03100/4

I/O terminals Digital outputs (C 125)

Terminal X2

Signal (Lenze setting)

Signal configuration

SB

"Application error" status

• The state bus is put in the "error" status.

C03100/5

I/O terminals Monitoring function "State bus" (C 127)

User LED

Signal (Lenze setting)

Signal configuration

Status "Electrical shaft enabled"

C03100/6

Drive interface LED status displays (C 34)

GA

AO1

AO2

GO

24O

DO1

DO2

DO3

DO4

GE

24E

SB