C02643, C02644, C02645 – Lenze E94AxHE Servo Drives 9400 HighLine (Firmware 01-37) User Manual

Page 632: C02646, C02647, C02648, 9400 highline | parameter setting & configuration

Advertising
background image

9400 HighLine | Parameter setting & configuration

Parameter reference

Parameter list | C02643

632

Firmware 1.37 - 09/2006

L

C02643

C02644

C02645

C02646

C02647

C02648

Parameter | Name:

C02643 | Ref. target position

Data type: INTEGER_32

Index: 21932

d

= 55AC

h

Basic function "

Homing

"

Setting range

(min. value | unit | max. value)

Lenze setting

-214748.3647

Unit

214748.3647 0.0000 Unit

;

Read access ; Write access … CINH … PLC STOP … No transfer … COM … MOT Scaling factor: 10000

Parameter | Name:

C02644 | Ref. speed 1

Data type: INTEGER_32

Index: 21931

d

= 55AB

h

Basic function "

Homing

"

Setting range

(min. value | unit | max. value)

Lenze setting

0.0000

Unit/s

214748.3647 360.0000 Unit/s

;

Read access ; Write access … CINH … PLC STOP … No transfer … COM … MOT Scaling factor: 10000

Parameter | Name:

C02645 | Ref. acceleration 1

Data type: INTEGER_32

Index: 21930

d

= 55AA

h

Basic function "

Homing

"

Setting range

(min. value | unit | max. value)

Lenze setting

0.0000

Unit/s²

214748.3647 720.0000 Unit/s²

;

Read access ; Write access … CINH … PLC STOP … No transfer … COM … MOT Scaling factor: 10000

Parameter | Name:

C02646 | Ref. speed 2

Data type: INTEGER_32

Index: 21929

d

= 55A9

h

Basic function "

Homing

"

Setting range

(min. value | unit | max. value)

Lenze setting

0.0000

Unit/s

214748.3647 180.0000 Unit/s

;

Read access ; Write access … CINH … PLC STOP … No transfer … COM … MOT Scaling factor: 10000

Parameter | Name:

C02647 | Ref. acceleration 2

Data type: INTEGER_32

Index: 21928

d

= 55A8

h

Basic function "

Homing

"

Setting range

(min. value | unit | max. value)

Lenze setting

0.0000

Unit/s²

214748.3647 360.0000 Unit/s²

;

Read access ; Write access … CINH … PLC STOP … No transfer … COM … MOT Scaling factor: 10000

Parameter | Name:

C02648 | Ref. S-ramp time

Data type: INTEGER_32

Index: 21927

d

= 55A7

h

Basic function "

Homing

"

Setting range

(min. value | unit | max. value)

Lenze setting

0

ms

10000 100 ms

;

Read access ; Write access … CINH … PLC STOP … No transfer … COM … MOT