3 machine parameters, 9400 highline | parameter setting & configuration – Lenze E94AxHE Servo Drives 9400 HighLine (Firmware 01-37) User Manual

Page 249

Advertising
background image

L

Firmware 1.37 - 09/2006

249

9400 HighLine | Parameter setting & configuration

Standard TAs

TA "Actuator – speed" | Machine parameters

11.2.3

Machine parameters

O

Tip!
In the »Engineer« the most important machine parameters can be adapted to the

machine on the Application parameter tab directly in the topmost Overview dialog

level:
Detailed information for selecting and entering the machine parameters can be

found in the chapter "

Drive interface

".

Machine parameters

(C 35)

Short overview of machine parameters

The machine parameters describe e.g. the motor end of the mechanics

used.
The setting of the machine parameters in the »Engineer» is carried out on

the Application parameters tab in the dialog level Overview  Drive

interface .

Parameters

Lenze setting

Value Unit

C00173

Mains - voltage

400/415 V

C00174

Threshold undervoltage (LU)

285 V

C00600

Resp. to DC bus overvoltage

Trouble

C02520

Gearbox fact. numer. motor

1

C02521

Gearbox fact. denom. motor

1

C02527

Motor mounting direction

Motor rotating CW

C02570

Controller configuration

Phase control

C02522

Gearbox fact. numer. load

1

C02523

Gearbox fact. denom. load

1

Description of the mechanics (load, tool)

C02528

Traversing range

Unlimited

C02524

Feed constant

360.0000 Unit

C02525

Unit

°

C02526

User-defined unit

°

C02533

Time unit

s

C00273/1

Motor moment of inertia

Motor-dependent kg cm

2

C00273/2

Load moment of inertia

0.00 kg cm

2

M

Advertising