1 status signals, 9400 highline | parameter setting & configuration – Lenze E94AxHE Servo Drives 9400 HighLine (Firmware 01-37) User Manual

Page 63

Advertising
background image

L

Firmware 1.37 - 09/2006

63

9400 HighLine | Parameter setting & configuration

Drive interface

System block "LS_DriveInterface"

4.7.1

Status signals

The following representation shows which status signals of the system block

LS_DriveInterface are set to TRUE in different typical cases:

Case 1:

Application has been transmitted to the controller.

No mains voltage available (LU fault).

Controller is inhibited (via RFR terminal).

Case 2:

Mains voltage has been connected.

Case 3:

Controller inhibit has been deactivated.

Case 4:

Fault is active.

Case 5:

Quick stop by trouble is active

Status

Status signal (output)

Ready for operation

z

z

DI_bReady

Fault is active

z

z

DI_bFailActive

Pulse inhibit is active

z

z

z

DI_bImpActive

Controller inhibit is active

z

z

z

DI_bCinhActive

Warning is active

DI_bWarningActive

Undervoltage detected

z

DI_bUVDetected

Overvoltage detected

DI_bOVDetected

Mains supply is Ok

z

z

z

z

DI_bMainSupplyOk

Ready to switch on

DI_bReadyToSwitchOn

Operation enabled

z

DI_bOperationEnabled