C00579, C00580, C00581 – Lenze E94AxHE Servo Drives 9400 HighLine (Firmware 01-37) User Manual

Page 588: 9400 highline | parameter setting & configuration

Advertising
background image

9400 HighLine | Parameter setting & configuration

Parameter reference

Parameter list | C00579

588

Firmware 1.37 - 09/2006

L

C00579

C00580

C00581

Parameter | Name:

C00579 | Resp. to speed monitoring

Data type: UNSIGNED_32

Index: 23996

d

= 5DBC

h

Response to release of speed monitoring
Selection list

(Lenze setting printed in bold)

0 No response
1 Error
2 Trouble
3 Quick stop by trouble
4 Warning locked
5 Warning

;

Read access ; Write access … CINH … PLC STOP … No transfer … COM … MOT

Parameter | Name:

C00580 | Resp. to encoder open circuit

Data type: UNSIGNED_32

Index: 23995

d

= 5DBB

h

Response to open circuit in encoder

For the use of the encoder as motor encoder: If an error occurs, the safe operation of the motor is no longer

ensured, therefore for safety reasons always the "Error" response should be set!

Selection list

(Lenze setting printed in bold)

0 No response
1 Error
2 Trouble
3 Quick stop by trouble
4 Warning locked
5 Warning

;

Read access ; Write access … CINH … PLC STOP … No transfer … COM ; MOT

Parameter | Name:

C00581 | Resp. to external fault

Data type: UNSIGNED_32

Index: 23994

d

= 5DBA

h

Response to an external error

Drive interface

Selection list

(Lenze setting printed in bold)

0 No response
1 Error
2 Trouble
3 Quick stop by trouble
4 Warning locked
5 Warning
6 Information

;

Read access ; Write access … CINH … PLC STOP … No transfer … COM … MOT