C00087, C00088, C00089 – Lenze E94AxHE Servo Drives 9400 HighLine (Firmware 01-37) User Manual

Page 553: C00090, C00091, C00092, C00099, C00100, Setting in, 9400 highline | parameter setting & configuration

Advertising
background image

L

Firmware 1.37 - 09/2006

553

9400 HighLine | Parameter setting & configuration

Parameter reference

Parameter list | C00087

C00087

C00088

C00089

C00090

C00091

C00092

C00099

C00100

Parameter | Name:

C00087 | Rated motor speed

Data type: UNSIGNED_32

Index: 24488

d

= 5FA8

h

Setting range

(min. value | unit | max. value)

Lenze setting

50

rpm

50000 4050 rpm

;

Read access ; Write access ; CINH … PLC STOP … No transfer … COM ; MOT

Parameter | Name:

C00088 | Motor - rated current

Data type: UNSIGNED_32

Index: 24487

d

= 5FA7

h

Setting range

(min. value | unit | max. value)

Lenze setting

0.01

A

1500.00 1.30 A

;

Read access ; Write access ; CINH … PLC STOP … No transfer … COM ; MOT Scaling factor: 100

Parameter | Name:

C00089 | Rated motor frequency

Data type: UNSIGNED_32

Index: 24486

d

= 5FA6

h

Setting range

(min. value | unit | max. value)

Lenze setting

0.1

Hz

1000.0 270.0 Hz

;

Read access ; Write access ; CINH … PLC STOP … No transfer … COM ; MOT Scaling factor: 10

Parameter | Name:

C00090 | Rated motor voltage

Data type: UNSIGNED_32

Index: 24485

d

= 5FA5

h

Setting range

(min. value | unit | max. value)

Lenze setting

50

V

15000 225 V

;

Read access ; Write access ; CINH … PLC STOP … No transfer … COM ; MOT

Parameter | Name:

C00091 | Motor - cosine phi

Data type: UNSIGNED_32

Index: 24484

d

= 5FA4

h

Setting range

(min. value | unit | max. value)

Lenze setting

0.50

1.00 0.80

;

Read access ; Write access ; CINH … PLC STOP … No transfer … COM ; MOT Scaling factor: 100

Parameter | Name:

C00092 | Motor - magnetising current

Data type: UNSIGNED_32

Index: 24483

d

= 5FA3

h

Display range

(min. value | unit | max. value)

0.00

A

500.00

;

Read access … Write access … CINH … PLC STOP … No transfer … COM … MOT Scaling factor: 100

Parameter | Name:

C00099 | Firmware version

Data type: VISIBLE_STRING

Index: 24476

d

= 5F9C

h

Format: "xx.xx.xx.xx" (main version, subversion, release version, build number)

;

Read access … Write access … CINH … PLC STOP … No transfer … COM … MOT

Parameter | Name:

C00100 | Service code

Data type: UNSIGNED_32

Index: 24475

d

= 5F9B

h

This code is used internally by the controller and must not be overwritten by the user!

Advertising