9400 HighLine | Parameter setting & configuration

Encoder evaluation

108

Firmware 1.37 - 09/2006

L

6

Encoder evaluation

This chapter informs how to use feedback systems for the motor control.

See also:

Parameterise motor encoder

(C 70)

Note!

The encoder position is stored safe against mains failure in the memory module

and is therefore known to the drive control even after the mains has been

switched.
The position resolution of higher-level applications follow the resolution of the

encoder which will be activated for the position control.
Behaviour of the home position after mains switching
If the home position/information is to be available after mains switching as well,

the setting

C02652

= "1: Keep" is required.

• One further condition for keeping the home position/information after

mains switching is the compliance with the maximally permissible angle of

rotation of the encoder which can be set in

C02653

.

• When resolvers or single-turn absolute value encoders are used and the

mains is switched off (24-V supply off), the drive may only be moved by ½

motor revolution since otherwise the home position will get lost due to the

ambiguity of the encoder information.



Danger!

When using the encoder/resolver as motor encoder:
In case of an error as safe motor operation cannot be ensured anymore. Thus, the

"Fault" response (Lenze setting) should be set permanently for the (open circuit)

monitoring of the encoder/resolver!

C00580

: Response to open circuit of encoder

C00586

: Response to open circuit of resolver

C00601

: Response to communication error of encoder