C01196, C01203, C01204 – Lenze E94AxHE Servo Drives 9400 HighLine (Firmware 01-37) User Manual

Page 610: C01205, C01206, C01208, C01196/1, The permissible motor current, More or less switched off by setting, C01196/2

Advertising
background image

9400 HighLine | Parameter setting & configuration

Parameter reference

Parameter list | C01196

610

Firmware 1.37 - 09/2006

L

C01196

C01203

C01204

C01205

C01206

C01208

Parameter | Name:

C01196 | S1 torque characteristic I²xt mon.

Data type: UNSIGNED_32

Index: 23379

d

= 5B53

h

I

2

xt motor monitoring: Speed-dependent evaluation of the motor current

• By selecting a characteristic the permissible motor current is evaluated depending on speed for calculating the

thermal motor utilisation.

Setting range

(min. value | unit | max. value)

0

%

600

Subcodes

Lenze setting

Information

C01196/1

0 %

S1 torque characteristic n1/nn

C01196/2

100 %

S1 torque characteristic I1/In

C01196/3

0 %

S1 torque characteristic n2/nn

C01196/4

100 %

S1 torque characteristic I2/In

C01196/5

100 %

S1 torque characteristic n3/nn

C01196/6

100 %

S1 torque characteristic I3/In

C01196/7

100 %

S1 torque characteristic n4/nn

C01196/8

100 %

S1 torque characteristic I4/In

;

Read access ; Write access … CINH … PLC STOP … No transfer … COM ; MOT

Parameter | Name:

C01203 | Counter: Brake chopper overload

Data type: UNSIGNED_16

Index: 23372

d

= 5B4C

h

Display range

(min. value | unit | max. value)

0

65535

;

Read access … Write access … CINH … PLC STOP … No transfer … COM … MOT

Parameter | Name:

C01204 | Counter: Ixt overload

Data type: UNSIGNED_16

Index: 23371

d

= 5B4B

h

Display range

(min. value | unit | max. value)

0

65535

;

Read access … Write access … CINH … PLC STOP … No transfer … COM … MOT

Parameter | Name:

C01205 | Counter: DC bus overvoltage

Data type: UNSIGNED_16

Index: 23370

d

= 5B4A

h

Display range

(min. value | unit | max. value)

0

65535

;

Read access … Write access … CINH … PLC STOP … No transfer … COM … MOT

Parameter | Name:

C01206 | Counter: Mains switching

Data type: UNSIGNED_16

Index: 23369

d

= 5B49

h

Display range

(min. value | unit | max. value)

0

65535

;

Read access … Write access … CINH … PLC STOP … No transfer … COM … MOT

Parameter | Name:

C01208 | Counter: heatsink overtemp.

Data type: UNSIGNED_16

Index: 23367

d

= 5B47

h

Display range

(min. value | unit | max. value)

0

65535

;

Read access … Write access … CINH … PLC STOP … No transfer … COM … MOT

Advertising