C00416, C00420, C00421 – Lenze E94AxHE Servo Drives 9400 HighLine (Firmware 01-37) User Manual

Page 583: C00422, C00427, 9400 highline | parameter setting & configuration

Advertising
background image

L

Firmware 1.37 - 09/2006

583

9400 HighLine | Parameter setting & configuration

Parameter reference

Parameter list | C00416

C00416

C00420

C00421

C00422

C00427

Parameter | Name:

C00416 | Resolver error correction

Data type: UNSIGNED_32

Index: 24159

d

= 5E5F

h

Setting range

(min. value | unit | max. value)

Lenze setting

0

99999999 0

;

Read access ; Write access ; CINH … PLC STOP … No transfer … COM ; MOT

Parameter | Name:

C00420 | Number of increments of the encoder

Data type: UNSIGNED_16

Index: 24155

d

= 5E5B

h

Setting range

(min. value | unit | max. value)

Lenze setting

1

16384 512

;

Read access ; Write access ; CINH … PLC STOP … No transfer … COM ; MOT

Parameter | Name:

C00421 | Encoder voltage

Data type: UNSIGNED_16

Index: 24154

d

= 5E5A

h

Setting range

(min. value | unit | max. value)

Lenze setting

5.0

V

9.0 5.0 V

;

Read access ; Write access ; CINH … PLC STOP … No transfer … COM ; MOT Scaling factor: 10

Parameter | Name:

C00422 | Encoder type

Data type: UNSIGNED_16

Index: 24153

d

= 5E59

h

Selection list

(Lenze setting printed in bold)

0 Incremental encoder (TTL signal)
1 Sin/cos encoder
2 Absolute value encoder (Hiperface)
3 Absolute value encoder (EnDat)

;

Read access ; Write access ; CINH … PLC STOP … No transfer … COM ; MOT

Parameter | Name:

C00427 | TTL encoder signal evaluation

Data type: UNSIGNED_16

Index: 24148

d

= 5E54

h

Selection list

(Lenze setting printed in bold)

0 4x evaluation (A, B)
1 A:Increments B:Sign
2 Increments A:pos. B:neg.

;

Read access ; Write access ; CINH … PLC STOP … No transfer … COM ; MOT

Advertising