1 basic signal flow, 9400 highline | parameter setting & configuration – Lenze E94AxHE Servo Drives 9400 HighLine (Firmware 01-37) User Manual

Page 372

Advertising
background image

9400 HighLine | Parameter setting & configuration

TAs for positioning tasks

TA "Multi-purpose positioning" | Basic signal flow

372

Firmware 1.37 - 09/2006

L

13.2.1

Basic signal flow

The functional core of the multi-purpose positioning is formed by the sequence table and

the profile data management, which transmit the required control signals and profile data

to the basic drive function "Positioning".

[13-3] Signal flow of the TA "Multi-purpose positioning" (schematic diagram)

Multi-purpose positioning


Sequence table



Profile data management



Speed/acceleration override

Basic drive functions


Homing



Positioning



Manual jog



Stop



Quick stop

Limiter

!

Brake control (optional)

3

0

2

4

6

7

8

9

1

5

DI7

DI6

AIN1

PositionerTable

Profiles

Multi-purpose positioning

Override

Enable

AIN2

Speed override

Acceleration override

Sequencer

LS_ManualJog

n

t

и

з

LS_Brake

n

t

LS_Limiter

n

t

LS_Quickstop

STOP

n

t

LS_Stop

internal
status machine

Status

machine

(basic drive

functions)

Basic drive functions

M

0

-100

100 200

LS_Homing

n

t

LS_Positioner

DI2

DI4

DI3

DI1

DI5

Reset

Sequencer

input 8

DI8

Advertising