3 system block "ls_positioner, System block "ls_positioner, 9400 highline | parameter setting & configuration – Lenze E94AxHE Servo Drives 9400 HighLine (Firmware 01-37) User Manual

Page 180

Advertising
background image

9400 HighLine | Parameter setting & configuration

Basic drive functions

Positioning | System block "LS_Positioner"

180

Firmware 1.37 - 09/2006

L

9.6.3

System block "LS_Positioner"

The LS_Positioner system block in the function block editor maps the basic function

"Positioning".

Inputs

Identifier

DIS code | data type

Information/possible settings

POS_bEnable

C02679/1

| BOOL

Requesting control via the basic function

TRUE If no other basic function is active, a changeover to the function state

"Posiioning active" is effected and positioning can be executed via

the control inputs.

TRUEÌFALSE An active positioning is stopped, i. e. a changeover from the active

function state "Positioning active" via the function state "Drive is

stopped" back to the basic state "Drive in standstill" is effected.

POS_bStart

C02679/2

| BOOL

Starting positioning

FALSEÊTRUE The profile POS_ProfileData is executed.
FALSEÊTRUE

(once again)

"Restart"

• During an active positioning, another profile can be specified via

the input POS_ProfileData which is executed after restart.

POS_bAbort

C02679/3

| BOOL

Aborting or interrupting positioning

FALSEÊTRUE The current profile is not completed but braked to standstill with the

deceleration defined in the profile data.

TRUE A restart via POS_bStart or the continuation of an interrupted

positioning via POS_bRestart is inhibited.

FALSE A restart via POS_bStart or the continuation of an interrupted

positioning via POS_bRestart is possible again.

• If the restart signal POS_bRestart occurs during the acceleration

phase, the positioning is continued immediately.

POS_bRestart

C02679/4

| BOOL

Continuing an interrupted positioning process

• Only possible when POS_bAbort has been reset from TRUE to FALSE again.

TRUE The positioning interrupted before via POS_bAbort is completed.

• Distance already covered in a relative positioning process will be

considered.

POS_ProfileData

Pointer to the profile to be executed in internal units (increments)

• A profile chaining is caused by the pointer in the profile which points to the

sequence profile.

POS_bEnableOverride

C02679/5

| BOOL

Activating override

TRUE Override of speed and acceleration is active.

LS_Positioner

POS_bEnable

POS_bStart

POS_bAbort

POS_ProfileData

POS_bEnableOverride

POS_dnSpeedOverride_n

POS_dnState

POS_bActive

POS_bDone

n

t

POS_bRestart

POS_dnAccOverride_n

POS_bDisableTP

POS_bInTarget

POS_dnSetPos_p

POS_dnProfileTarget_p

POS_dnProfileSpeed_s

POS_dwActualProfileNumber

POS_bEnabled