3 system block "ls_quick stop, Block, Ls_quickstop – Lenze E94AxHE Servo Drives 9400 HighLine (Firmware 01-37) User Manual

Page 155: C 155), 9400 highline | parameter setting & configuration

Advertising
background image

L

Firmware 1.37 - 09/2006

155

9400 HighLine | Parameter setting & configuration

Basic drive functions

Quick stop | System block "LS_quick stop"

9.3.3

System block "LS_quick stop"

The LS_quick stop system block in the function block editor maps the basic function "Quick

stop".

Inputs

Outputs

Identifier

DIS code | data type

Information/possible settings

QSP_bActivate1

C02619/1

| BOOL

QSP_bActivate2

C02619/2

| BOOL

QSP_bActivate3

C02619/3

| BOOL

Activate quick stop

• The three inputs are linked via a logic OR gate.

TRUE If one of the three inputs is set to TRUE, it is changed to the function

state "Quick stop active" and the drive is braked to standstill within

the deceleration time set for quick stop.

TRUEÌFALSE When all three inputs are reset to FALSE, it is changed to a setpoint-

generating basic function (e.g. "speed follower") via the function

state "Drive is stopped".

Identifier

DIS code | data type

Value/meaning

QSP_bActive

C02619/4

| BOOL

Status output "quick stop is active"

TRUE Quick stop is active.

LS_Quickstop

QSP_bActivate1

QSP_bActive

STOP

n

t

³ 1

QSP_bActivate2

QSP_bActivate3