2 master value source: digital frequency input, 3 master value source: bus system, 9400 highline | parameter setting & configuration – Lenze E94AxHE Servo Drives 9400 HighLine (Firmware 01-37) User Manual

Page 343

Advertising
background image

L

Firmware 1.37 - 09/2006

343

9400 HighLine | Parameter setting & configuration

TAs for interconnection via electrical shaft

TA "Synchronism with mark synchronisation" | Selection of master value source and output

12.3.4.2

Master value source: Digital frequency input
To use the digital frequency input as master value source, the controller must be provided

with digital frequency extension module (E94AYFLF).
To ensure the integration of the extension module in the application, the TA "Synchronism

with mark synchronisation" must be used as technology application.

O

Tip!
Detailed information on the digital frequency extension module can be found in

the User Manual "Digital frequency extension module (E94AYFLF) – parameter

setting & configuration".

12.3.4.3

Master value source: Bus system
When the master value is selected via a bus system as e.g. system bus (CAN) it is possible

to first extrapolate the received position information to compensate higher bus

transmission cycles.

r

Parameter setting: Tab Application parameter  Dialog level Overview  Synchronism


Master value extrapolation

r

Configuration: Tab FB editor  FB MotionBusIn

Note!

The technology application "Synchronism with mark synchronisation"

MotionBus" which can also be selected in the application catalog does not

contain any interfaces to the digital frequency extension module.

Parameters

Lenze setting

Value Unit

C03550

Number of extrapolation cycles

1

Control inputs of the function

Signal configuration

Lenze setting

Control input

(Multiplexer parameters)

FALSE  Activate extrapolation

C03058/9

Advertising