C00069, C00070, C00071 – Lenze E94AxHE Servo Drives 9400 HighLine (Firmware 01-37) User Manual

Page 551: C00072, C00074, C00075, C00076, C00077, Under, And the reset

Advertising
background image

L

Firmware 1.37 - 09/2006

551

9400 HighLine | Parameter setting & configuration

Parameter reference

Parameter list | C00069

C00069

C00070

C00071

C00072

C00074

C00075

C00076

C00077

Parameter | Name:

C00069 | CPU temperature

Data type: INTEGER_32

Index: 24506

d

= 5FBA

h

Display range

(min. value | unit | max. value)

-200

°C

200

;

Read access … Write access … CINH … PLC STOP … No transfer … COM … MOT

Parameter | Name:

C00070 | Speed controller gain

Data type: UNSIGNED_32

Index: 24505

d

= 5FB9

h

Setting range

(min. value | unit | max. value)

Lenze setting

0

Nm/rpm

2000000000 44 Nm/rpm

;

Read access ; Write access … CINH … PLC STOP … No transfer … COM ; MOT Scaling factor: 100000

Parameter | Name:

C00071 | Speed contr. reset time

Data type: UNSIGNED_32

Index: 24504

d

= 5FB8

h

Setting range

(min. value | unit | max. value)

Lenze setting

1.0

ms

6000.0 14.4 ms

;

Read access ; Write access … CINH … PLC STOP … No transfer … COM ; MOT Scaling factor: 10

Parameter | Name:

C00072 | Speed controller D component

Data type: UNSIGNED_32

Index: 24503

d

= 5FB7

h

Setting range

(min. value | unit | max. value)

Lenze setting

0.00

ms

3.00 0.00 ms

;

Read access ; Write access … CINH … PLC STOP … No transfer … COM ; MOT Scaling factor: 100

Parameter | Name:

C00074 | current controller feedforward control

Data type: UNSIGNED_8

Index: 24501

d

= 5FB5

h

Selection list

(Lenze setting printed in bold)

0 Deactivate feedforward control
1 Activate feedforward control

;

Read access ; Write access … CINH … PLC STOP … No transfer … COM … MOT

Parameter | Name:

C00075 | Current controller gain

Data type: UNSIGNED_32

Index: 24500

d

= 5FB4

h

Setting range

(min. value | unit | max. value)

Lenze setting

0.00

V/A

750.00 105.00 V/A

;

Read access ; Write access … CINH … PLC STOP … No transfer … COM ; MOT Scaling factor: 100

Parameter | Name:

C00076 | Current contr. integr.-act. time

Data type: UNSIGNED_32

Index: 24499

d

= 5FB3

h

Setting range

(min. value | unit | max. value)

Lenze setting

0.01

ms

2000.00 2.00 ms

;

Read access ; Write access … CINH … PLC STOP … No transfer … COM ; MOT Scaling factor: 100

Parameter | Name:

C00077 | Field controller gain

Data type: UNSIGNED_32

Index: 24498

d

= 5FB2

h

Setting range

(min. value | unit | max. value)

Lenze setting

0.00

A/Vs

50000.00 165.84 A/Vs

;

Read access ; Write access … CINH … PLC STOP … No transfer … COM ; MOT Scaling factor: 100