C00150, C00155, 9400 highline | parameter setting & configuration – Lenze E94AxHE Servo Drives 9400 HighLine (Firmware 01-37) User Manual

Page 557

Advertising
background image

L

Firmware 1.37 - 09/2006

557

9400 HighLine | Parameter setting & configuration

Parameter reference

Parameter list | C00150

C00150

C00155

Parameter | Name:

C00150 | Status word 1

Data type: BITFIELD_16

Index: 24425

d

= 5F69

h

Status word 1 of the

drive interface

Value is bit-coded:

Bit 0 User-defined status (bit 0)
Bit 1 Pulse inhibit active
Bit 2 User-defined status (bit 2)
Bit 3 User-defined status (bit 3)
Bit 4 User-defined status (bit 4)
Bit 5 User-defined status (bit 5)
Bit 6 Actual speed value = 0
Bit 7 Controller inhibit active
Bit 8 Device state - Bit 1
Bit 9 Device state - Bit 2

Bit 10 Device state - Bit 3
Bit 11 Device state - Bit 4
Bit 12 Warning active
Bit 13 Trouble active
Bit 14 User-defined status (bit 14)
Bit 15 User-defined status (bit 15)

;

Read access … Write access … CINH … PLC STOP … No transfer … COM … MOT

Parameter | Name:

C00155 | Status word 2

Data type: BITFIELD_16

Index: 24420

d

= 5F64

h

Status word 2 of the

drive interface

Value is bit-coded:

Bit 0 Error status active
Bit 1 Torque limit reached
Bit 2 Current limit reached
Bit 3 Reserved
Bit 4 Drive switched on/in operation
Bit 5 Drive ready for operation
Bit 6 Error active
Bit 7 Drive initialisation
Bit 8 Motor CCW rotation active
Bit 9 Quick stop by trouble active

Bit 10 Safe torque off active
Bit 11 Application active
Bit 12 Reserved
Bit 13 Reserved
Bit 14 Quick stop active
Bit 15 Reserved

;

Read access … Write access … CINH … PLC STOP … No transfer … COM … MOT

Advertising