C02708, C02709, C02710 – Lenze E94AxHE Servo Drives 9400 HighLine (Firmware 01-37) User Manual

Page 640: C02711, C02708/1, C02709/1, C02710/1, C02711/1, C02708/2, C02710/2

Advertising
background image

9400 HighLine | Parameter setting & configuration

Parameter reference

Parameter list | C02708

640

Firmware 1.37 - 09/2006

L

C02708

C02709

C02710

C02711

Parameter | Name:

C02708 | Limited speed

Data type: INTEGER_32

Index: 21867

d

= 556B

h

Basic function "

Limiter

"

Setting range

(min. value | unit | max. value)

0.0000

Unit/s

214748.3647

Subcodes

Lenze setting

Information

C02708/1

3600.0000 Unit/s

Limited speed 1 ... 4

C02708/2

7200.0000 Unit/s

C02708/3

14400.0000 Unit/s

C02708/4

28800.0000 Unit/s

;

Read access ; Write access … CINH … PLC STOP … No transfer … COM … MOT Scaling factor: 10000

Parameter | Name:

C02709 | Limited speed

Data type: INTEGER_32

Index: 21866

d

= 556A

h

Basic function "

Limiter

"

Display range

(min. value | unit | max. value)

0.0

rpm

214748364.7

Subcodes

Information

C02709/1

Limited speed 1 ... 4

C02709/2
C02709/3
C02709/4

;

Read access … Write access … CINH … PLC STOP … No transfer … COM … MOT Scaling factor: 10

Parameter | Name:

C02710 | Delay lim. speed

Data type: UNSIGNED_32

Index: 21865

d

= 5569

h

Basic function "

Limiter

"

Setting range

(min. value | unit | max. value)

0.0000

Unit/s²

214748.3647

Subcodes

Lenze setting

Information

C02710/1

0.0100 Unit/s²

Delays for limited speed 1 ... 4

C02710/2

0.0100 Unit/s²

C02710/3

0.0100 Unit/s²

C02710/4

0.0100 Unit/s²

;

Read access ; Write access … CINH … PLC STOP … No transfer … COM … MOT Scaling factor: 10000

Parameter | Name:

C02711 | S-ramp time lim. speed

Data type: UNSIGNED_32

Index: 21864

d

= 5568

h

Basic function "

Limiter

"

Setting range

(min. value | unit | max. value)

0

ms

10000

Subcodes

Lenze setting

Information

C02711/1

100 ms

S-ramp times for limited speed 1 ... 4

C02711/2

100 ms

C02711/3

100 ms

C02711/4

100 ms

;

Read access ; Write access … CINH … PLC STOP … No transfer … COM … MOT